Introducing the new ET24 In-Line Telemetry Lift Link Load Cell… More Accurate: ±0.3% of reading More Adaptable: Wireless monitoring from multiple locations and load cells More Available: 3-4 days delivery time Cutting Edge Power Management System The new ET24 telemetry lift link load cell’s contemporary power management means transmission distances in excess of 200 metres are achievable in open-field situations, avoiding the expense and problematic use of cabling. The telemetry lift link’s batteries will last for more than 600 hours with the batteries in the handheld display lasting up to 40. There’s no need to worry about finding special batteries either as both the load cell and display use any standard AA alkaline type. The antenna is internal so there’s no […]
Transducer News & Views | The Applied Measurements Blog
CCG Annular Load Cell Flexible in Design, Flexible in Application
Introducing the CCG family of annular load cells: Applied Measurements are proud to present the CCG family of annular load cells. These annular or donut load cells have been designed for the measurement of compressive forces, both continually and periodically, and are often used in critical bolted installations to monitor bolt tension. One major benefit is that the CCG annular load cells can be entirely customised to suit your specific application. The CCG annular load cell is flexible in: All dimensions – Fits into spaces which limit the use of other load cells. Our lowest height to date standing at a tiny 5mm tall! IP rating – IP66 as standard, can be enhanced to IP68 for submersible applications. Temperature range […]
Applied Measurements’ Displacement Transducers Make Tracks Through Turkey
Applied Measurements were asked to design a bespoke bridge monitoring system for Turkey’s new rail tunnel – The Marmaray Project. We created a bespoke bridge monitoring system using 3 off 50mm AML/SGD displacement transducers, forming a triaxial measurement of each joint. The AML/SGD series of displacement transducers utilise strain gauge technology to convert the linear movement of the joints within the tunnel into an analogue electrical signal. The AML/SGD series of displacement transducers were chosen for their excellent accuracy (0.1%), coupled with their high resolution and long-term stability, making them a perfect transducer for The Marmaray Project.
DSC-USB Digitiser Connects Strain Gauge Sensors to Your PC Quickly and Easily
Want an easy and cost effective way to convert a transducer signal to a digital input for your PC? Try Applied Measurements’ compact DSC-USB strain gauge digitiser. This compact digital signal conditioner delivers high performance and high accuracy measurement readings from any full-bridge strain gauge sensor direct to your PC, via your USB port. Using the free DSC toolkit software means you can view the readings immediately on your PC and interpret the data instantly, with no need for additional amplifiers. With its USB connectivity, the DSC-USB can provide high stability readings direct to your computer and as the DSC-USB is available ex-stock for £249, it can be delivered without delay, enquire today. The device is powered by the USB port […]
Applied Measurements’ Submersible Load Cells fitted to the World’s Largest All-Terrain Hexapod
Applied Measurements provided the load cells needed to monitor the force on individual legs to stop the Mantis (the world’s largest hydraulic hexapod robot) walking into a situation that is hazardous to its overall stability. Assisted by Applied Measurements’ compact and submersible DSCC load cells, the Mantis successfully travels over all slopes and uneven surfaces, traversing most types of terrain, even wading through water.
Submersible Subsea Load Cells Excel Under Pressure
With over 20 years experience designing and manufacturing submersible and subsea load cells, it’s no wonder Applied Measurements have sensors functioning worldwide, from a few metres below the surface to 10 kilometres underwater (depth or pressure equivalencies). These submersible and subsea sensors operate precisely and reliably 24/7 in applications including underwater structure lifting systems, ROVs and offshore power generation. Many of our load cell designs are based on standard products with modifications to allow operation in underwater environments; O-ring seals, welded housings and moulded subsea connector assemblies ensure high integrity even at great depths. The most common models are our CCD column type compression load cells; DBCL in-line tension and compression load cells (image shown), which cover higher capacities from […]
New USB T24 Telemetry Base Station Released
The T24 wireless telemetry aquisition range has expanded its portfolio of products with a new USB telemetry base station. The new T24-BSue compact USB telemetry base station sits between the miniature T24-BSu telemetry base station and the fully-featured T24-BSi industrial telemetry base station and offers an ideal mix of compact dimensions and an extended range of 200 metres. The T24-BSue’s IP65-rated (weatherproof) enclosure, shared with the T24-ACMi acquisition module, measures just 59 x 76.6 x 29mm and is manufactured in tough plastic providing excellent environmental protection whether the device is being used indoors or outside exposed to the elements. The new USB base station is fully compatible with the complete range of T24 wireless telemetry acquisition modules which includes models […]
DBB Series S-Beam Load Cell Range Extended to 10 tonnes
Applied Measurements is excited to announce the expansion of the DBB series of S-Beam load cells to include a 10,000kg /100kN model, extending the already diverse range of potential applications further still. The DBB range of load cells are generally available ex-stock regardless of capacity, and are easily matched with an array of instrumentation including amplifiers, indicators and digitisers, many of which are also ex-stock. Our S-Beam load cells are used in many applications from hopper weighing and tensile testing to bicycle spoke force measurement and equine research. For a portable stand-alone system, any DBB load cell can be wired into the AMLTR-150 battery powered, hand held display, while the INT2-L panel mounted indicator is versatile giving you lots of analogue […]