Quick Enquiry


    Thanks for your enquiry. We'll be in touch soon.
    Get our latest product and application news sent directly to your inbox.
    Name: 
    Your email address:*
    Consent:*
    Please enter all required fields Click to hide
    Correct invalid entries Click to hide

    Our last shipping day this year is Thursday 19th of December 2024 and our office and workshop will be closed for Christmas from Tuesday 24th of December 2024, re-opening on Thursday 2nd of January 2025. Orders placed in the web shop will be processed on our return. Thank you for your patience and Happy Christmas!

    Microtronics BlueForce Troubleshooting

    Downloads

    Software updates for Blueforce version 3.0 and newer. To update the software on an old BlueForce version (e.g. 2.0), please contact Microtronics directly [email protected].

    General

    Can you repair my Microtronics BlueForce Tester?

    No, we are a calibration house only and can only offer calibration of the gate force testers. Repairs can only be carried out in Italy by the manufacturer Microtronics. You will need to contact the company that supplied you with the tester originally to discuss their warranty and repair procedure.

    What is the difference between the BlueForce Smart and the New BlueForce Smart PRO?

    The BlueForce Smart PRO delivers the test measurement results via GSM web connectivity directly to any web-connected device. It uploads the calibration details directly to the CLOUD software. The Smart PRO Tester now includes the physical orientation of the tester (i.e. horizontal or vertical) and the GPS geographical location. Plus, continuous push force measurement (eg. panic bars) is now possible with the new dynamometer auxiliary function, now included, which shows directly on the display. See here for more details.

    The BlueForce Smart delivers the measurements via NFC or BlueTooth.

    How quickly can you calibrate my gate impact force tester?

    We offer 2 levels of service – 7 working day and 3 working day from receipt of your gate impact force tester. For Smart Upgrade it’s 14 working days.

    What is the carriage charge for returning my gate force tester?

    Return carriage is included free of charge to UK mainland addresses.

    I want my Microtronics BlueForce/SpeedForce impact force tester calibrated, what do I do now?

    Download and fill in the Gate Force booking in Form and send it in with your device to:

    Applied Measurements Ltd
    Microtronics Calibration Department
    6 Mercury House
    Calleva Park
    Aldermaston
    Berkshire
    RG7 8PN

    As soon as we receive your unit in, we will contact you using the details you provided on the form.

    How can I pay for my Microtronics calibration?

    The easiest way is to pay by Visa or Mastercard (debit and credit), unfortunately, we do not accept AMEX. We only charge the card on the day of shipment. If you wish to be put on 30-day credit terms, please let us know when initially ordering by ticking ‘Account’ payment terms box. 30-day credit accounts are subject to credit clearance first which may affect your shipment date.

    BlueForce App

    My BlueForce Phone App is not pairing with my BlueForce Smart Device

    Correct settings for using the BlueForce APP

    ATTENTION! If you have tried Bluetooth pairing or entered device/Bluetooth pairing codes, you need to delete BlueForce Smart from the list of devices on your Smartphone/Tablet. Then restart it.
    ATTENTION! If the BlueForce Smart is connected to your PC with the USB cable or with the Plug’n Go device, you must disconnect it and restart the force tester.

    Excluding these two conditions, set up/verify your device with the following indications:

    Verify that the operating system of the Smartphone/Tablet device is equal to or greater:
    iOS: 9.0
    Android: 5.0

    Verify that the following settings are enabled on your device

    Bluetooth / NFC / GPS
    Network data connection or WI-FI

    N.B. stand-by functions must be disabled

    Start the Blueforce Smart APP and then make a test measurement with the force tester, after a few seconds the parameters and the graph will be displayed on your smartphone / Tablet, if the APP remains waiting without showing anything refer to the next paragraphCorrect settings for using the BlueForce APP

    The BlueForce Phone App is not receiving measurements using NFC

    BlueForce APP does not receive measurements sent by the force tester – Using the NFC System

    Carefully check the phone settings indicated in the previous paragraph

    For Android devices, it is advisable to clear the browsing history

    In some cases, it is necessary to restart the Smartphone/Tablet

    If the Bluetooth system is not compatible, it is advisable to use the NFC system that allows you to transfer the last test carried out by placing your device on the back of the BlueForce Smart, then:

    Verify that the operating system of the Smartphone/Tablet device is:

    iOS devices: from iOS 13.0 and devices from iPhone 7 onward
    Android devices: from o.s. 5.0 (N.B. in some cases it is necessary to clear the history of the Browser)

    Activate the NFC function on the menu of the Smartphone/Tablet device

    Make a test measurement with the force tester, then place your device on the back of the force tester and wait for the request / display of the measurement made (it is not necessary to start the BlueForce APP).BlueForce APP does not receive measurements - the NFC System

    BlueForce Smart

    I am getting an Err2 or Err3 message when trying to send measurements to the PC software

    The force tester does not send the stored measurements to the software – Err2, Err3 Message

    The errors reported on the display of the Blueforce / SpeedForce / BlueForce Smart, indicate the failure to connect with the PC or software:

    Err 3 – Check that the USB cable is properly connected to the PC

    Err 2 – The connected force tester does not communicate with the software (check the software setting here)Err2 Err3 Messages

    Err2 Message

    Setting the serial port on the software, force tester not detected, Err2

    Turn on the PC and then connect the force tester with the USB cable or with the Plug’n Go device (if supplied).

    N.B. if possible always use the same USB port of the PC.

    Launch the BlueForce software, if you do not see pop-ups or warnings, the force tester is connected regularly and the serial port has configured itself automatically (use the SEND function to download the stored measurements, see here).

    If you see the warning “serial port of pinch-force instrument not open” you need to configure the serial port in the software settings:
    Verify that the force tester is connected with the USB cable or Plug’n Go device (if supplied)
    Open the menu File -> Settings -> Serial
     Port ->
     Select the correct COM
    N.B. if there is a black dot, click on the dot again
    Exit the menu and re-enter to check the setting (black dot to the left of the COM port)
    On the force tester use the SEND function to download the stored measurements, see hereSetting the serial port on the software - force tester not detected Err2

    Err3 Message

    Check that the USB cable is properly connected to the PC

    The force tester does not send stored measurements to the software with the Plug’n Go (Bluetooth) device

    Check that the mode of connection to the PC is set correctly, then enter the menu File -> Settings -> Serial
     Port
     -> Pc Connection Mode ->
    select Plug device.

    N.B. If you have recently UPGRADED the force tester, without having sent the Plug’n Go Bluetooth device, communication with the software does not take place (contact Microtronics for updating the Plug’n Go device).send stored measurements to the software with the Plug'n Go

    How to perform a test measurement with the force tester

    Place the force tester on a flat surface, turn it on then place on the first free memory with the right button [e.g. 1 . . . .]

    Make a strong pressure with the hand on the head of the force tester, then in 5 seconds the measurement is acquired [1 A . . .], then stored and simultaneously sent to the integrated Bluetooth / NFC system (if you use the BlueForce APP you can immediately consult the test on the Smartphone / Tablet device)

    At the end the stored measurement is displayed with the number without dots [1    ]

    To download the test to your PC follow the next paragraph, sending stored measurementsHow to perform a test measurement with the force tester

    How to send the measurements stored in the force tester to the software

    Turn on the PC and then connect the force tester with the USB cable or the Plug’n Go (if supplied)

    Start the BlueForce software and turn on the force tester, then with the left button, go to the FUNC menu, then with the right button look for the SEND function, then press the right button again for 2 seconds to send the measurements.

    The SEND function will flash to indicate the “downloading of the measurements” to the software, (if the force tester indicates the Err2 message, see the paragraph “serial port setting” here)

    The SEND function sends all measurements stored in the force tester to the software, completely emptying the memoryHow to send the measurements stored in the force tester to the software

    BlueForce Software

    I need to update the software on an old BlueForce version (e.g. 2.0)

    Please contact Microtronics directly [email protected]

    I need to update the software on my Blueforce version 3.0 version

    The latest Microtronics software is available to download here from Microtronics.

    I need the software and operating instructions for the Microtronics BlueForce

    The complete software and operating instructions of Microtronics BlueForce can be downloaded here.
    For custom software, please contact Microtronics directly [email protected].

    Calibration expired warning despite the force tester being regularly calibrated

    It is necessary to download at least one test in the software so that it can recognize the regular calibration date, if the warning persists check these settings:

    Check that the PC date is correct

    If you have more force testers, another model may be configured (see BlueForce software -> settings menu -> Info -> Model), if different set the correct model.

    Backup of stored measurements/customers (database)

    If you want to re-install the software or to make a backup of the database (which contains customer and test data), we recommend that you make a copy of the database in an external memory:

    In the BlueForce software enter the menu File -> Archive Manager -> Path, the “path” displayed is the default one where the database is stored (normally in the Documents folder)

    Click on the path then select the external drive for storage (e.g. a USB memory)

    Then (in case you need to install a new copy of the BlueForce software), just copy the content stored in the external memory in the same default location indicated in the software in the menu File -> Archive Management -> Path

    In case you want to use the database from another location, you need to enter the menu File -> Archive Management -> Select Archive, and then select the database from the folder blueforce -> databaseBackup of stored measurements customers database

    Changing Incorrectly Assigned Measurements

    If measurements have been stored on an incorrect door (or referred to another regulation) it is necessary to transfer them to the correct door following this procedure:

    Rename the door to another name (e.g. Wrong Entry Gate) using the edit menu (with the right button of the mouse)

    Then create/insert the new door with the correct name (e.g. Entrance Gate)

    From the “detail” area of the software drag the measurements (incorrectly associated) to the affected points of the new door

    After this operation, you can delete the previous incorrect door.Changing Incorrectly Assigned Measurements

    Videos

    Key Features of the New BlueForce Smart PRO
    How to use the BlueForce Smart PRO and BlueForce CLOUD software.
    BSI Assurance Mark ISO 9001:2015 FS677584
    We Are a Living Wage Employer
    Cyber Essentials Certified