At a Glance
- Ranges: 0-1bar up to 0-700bar
- Outputs: 4-20mA, 0-5Vdc, 0-10Vdc, 0.5-4.5Vdc, mV/V
- Environmental Protection: IP68 Rated to 3000m Depth (300bar External Pressure)
- Accuracy: <±0.25%/FS (0.1% option)
- Rugged Duplex Stainless Steel Construction
- Ideal for Subsea Pipeline Monitoring & Oil & Gas Exploration
- Submersible IP68 to 3000m Depth/300 bar External Pressure as Standard
- Precision <±0.25% Accuracy (0.1% Optional)
- Wet-Mateable 3-pin or 4-pin Subsea Connector
- Sealed Gauge or Absolute Reference Versions
- ASIC-based amplifier circuit
Description
Our Applied Measurements Pa600SS subsea pressure sensor series are ideal for the measurement of gas and liquid pressure in subsea and offshore applications. They have a submersible IP68 protection rating for depths of up to 3000m (300bar external pressure) and a UNS S31803 Duplex stainless steel construction as standard. Greater depths ratings to 8000m/800bar are also available on request.
Thanks to their wet-mateable 3-pin or 4-pin subsea connector type electrical connection, integrity at 3000m depths/300bar is guaranteed. Plus, along with their ±0.25% of full-scale accuracy as standard, precision and optimum performance is ensured. If your application requires even further accuracy, we can also provide a 0.1% optional version.
Viton O-ring, Duplex stainless steel case, ceramic diaphragm (96% aluminium oxide Al2O3) and a G¼ inch male process connection come as standard with the Pa600SS subsea pressure sensor. Plus, Applied Measurements can provide alternate case, O-ring material and process connections to suit your requirement. We can also provide improved thermal zero stability of <±0.02% or <±0.01%/Span/˚C.
The Pa600SS subsea series provides a wide choice of electrical outputs from its ASIC-based amplifier circuit, these include 4-20mA, 0-5Vdc, 0-10Vdc, 10mV/V and 20mV/V, as well as a ratiometric 0.5-4.5Vdc (10% to 90% of supply voltage) signal that requires a 5Vdc (2.7 – 5.5Vdc acceptable) to suit most dataloggers.
The Pa600SS subsea pressure sensor series can also be supplied with any of our wide range of instrumentation to give you a complete calibrated system.
Technical Specifications
Nominal Pressure Range | Bar (sealed gauge or absolute) | 0-1 | 0-2 | 0-5 | 0-10 | 0-20 | 0-50 | 0-100 | 0-250 | 0-400 | 0-600 | 0-700 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Compound Ranges | Bar | -1…0 * | -1…+2 * | -1…+5 | -1…+9 | -1...+19 | -1...+29 | - | - | - | - | - |
Permissible Overpressure | Bar | 2 | 4 | 10 | 20 | 40 | 100 | 200 | 400 | 575 | 800 | 800 |
Burst Pressure | Bar | 4 | 5 | 12 | 25 | 50 | 120 | 250 | 500 | 650 | 950 | 950 |
*<±0.1% / FS (BFSL) accuracy not possible in this range |
Output Signal & Supply Voltage | Wiring System | Output | Supply Voltage | Input Current | Input Resistance | Output Resistance |
---|---|---|---|---|---|---|
Pa642SS | 2 - wire | 4 – 20 mA | 9 – 32 Vdc | n/a | <500 | <500 |
Pa605SS | 3 - wire | 0 – 5V dc | 9 – 32 Vdc | <10 mA | <500 | <500 |
Pa6010SS | 3 - wire | 0 – 10V dc | 13 – 32 Vdc | <10 mA | <500 | <500 |
Pa645SS | 3 - wire | 0.5 to 4.5V dc | 5 Vdc (2.7 - 5.5Vdc) | <3 mA | <500 | <500 |
Pa602SS | 4 - wire | Passive mV/V (un-rationalised) | 2 – 30 Vdc | <1 mA @ 10V | <11000 | <11000 |
Pa607SS | 4 - wire | 2mV/V (rationalised) | 2 – 30 Vdc | <1 mA @ 10V | <11000 | <11000 |
Pa610SS | 4 - wire | 10mV/V (amplified) | 3 – 12 Vdc | <3 mA typ. | <11000 | <2000 nom. |
Pa620SS | 4 - wire | 20mV/V (amplified) | 3 – 12 Vdc | <3 mA typ. | <11000 | <2000 nom. |
Performance | ||
---|---|---|
Accuracy (non-linearity, hysteresis, repeatability) | % Full Scale Output | <±0.25 (BFSL) <±0.1 (BFSL) optional |
Zero Balance | ±% of Rated Output | <1.0 |
Setting Errors (offsets) | 2-wire, 3-wire 4-wire rationalised 4-wire un-rationalised | Zero & Full Scale, <±0.5% / FS Zero <0.2mV/V, span ±1% Zero<0.1mV/V, Span ±30% |
Permissible Load | 2-wire 3-wire 4-wire | Rmax = [(VS – VS min) / 0.02] Ω Rmin = 10 k Ω Rmin = 11 k Ω |
Influence Effects | Supply Effects Load Effect | mV/V & 0.5 to 4.5V – Ratiometric, Other Voltage Outputs - <0.005 % FS / 1V 4-20mA = <0.05 % FSO / kΩ |
Response Time (10% - 90%) | ms | ≤1 (mV/V versions) ≤10 (amplified versions) |
Warm-Up Time (amplified versions only) | ms | 2 typ. |
Permissible Temperatures & Thermal Effects | ||
---|---|---|
Media Temperature | ˚C | -20 to +135 (non-freezing media only) |
Ambient Temperature | ˚C | -4 to +60 |
Storage Temperature | ˚C | -20 to +60 |
Compensated Temperature Range | ˚C | +20 to +60 |
Thermal Zero Shift (TZS) | % / FS / ˚C | <±0.04 (standard) <±0.02 (option) <±0.01 (option) |
Thermal Span Shift (TSS) | % output / ˚C | <±0.015 typical |
Electrical Protection | ||
---|---|---|
Reverse Polarity Protection | No damage but also no function | |
Electromagnetic Compatibility | CE Compliant | |
Insulation Resistance | Megohms Ω at 50V dc | >500 |
Mechanical Stability | |
---|---|
Shock | 100 g / 11 ms |
Vibration | 10 g RMS (20 ... 2000 Hz) |
Materials | |
---|---|
Housing & process connection | UNS S31803 Duplex Stainless Steel CA104 Marine Bronze or Titanium (optional) |
Process Connection ‘O’ ring seal | FKM/Viton NBR/Nitrile (optional) EPDM (optional) FFKM / Chemraz (optional) |
Housing 'O' ring seals | FKM/Viton + NBR/Nitrile |
Diaphragm | Ceramic Al2O3 96 % |
Media wetted parts | Housing and process connection, ‘O’ ring seal, diaphragm |
Misc | ||
---|---|---|
Weight | grams | 150 nominal |
Installation position | Any | |
Operational life | pressure cycles | > 100 x 106 |
Environmental Protection | IP68 to 3000m/300bar | |
Subsea Connector Type | SubConn® Circular Series Bulkhead | 3-Pin Male (2-wire sensors) / 4-Pin Male (3-wire & 4-wire sensors) |
Product Dimensions
All dimensions are in mm
Wiring Details
Subsea Connector | ||
---|---|---|
2 - wire | +ve Supply -ve Supply Ground | Pin 1 Pin 2 Pin 3 |
3 - wire | +ve Supply -ve Supply +ve Output Ground | Pin 1 Pin 2 Pin 3 Pin 4 |
4 - wire | +ve Supply -ve Supply +ve Output -ve Output | Pin 1 Pin 2 Pin 3 Pin 4 |
Ordering Codes & Options
Pa642SS-10barsg-A4AV-00-000 | Pa6 | 42 | SS | - | 10barsg | - | A | 4 | A | V | - | 00 | - | 000 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Family | ||||||||||||||
Pa6 | Pa6 | |||||||||||||
Electrical Output | ||||||||||||||
02 = mV/V un-rationalised | 02 | |||||||||||||
07 = 2mV/V | 07 | |||||||||||||
10 = 10mV/V | 10 | |||||||||||||
20 = 20mV/V | 20 | |||||||||||||
42 = 4-20mA (2-wire) | 42 | |||||||||||||
45 = 0.5-4.5Vdc ratiometric (5V excitation) | 45 | |||||||||||||
05 = 0-5Vdc | 05 | |||||||||||||
010 = 0-10Vdc | 010 | |||||||||||||
Electrical Connection | ||||||||||||||
SS = Subsea Connector | SS | |||||||||||||
Pressure Range | ||||||||||||||
10barsg = 0 to 10bar sealed gauge | - | 10barsg | ||||||||||||
M1P1barsg = -1 to +1bar sealed gauge | - | M1P1barsg | ||||||||||||
5bara = 0 to 5bar absolute | - | 5bara | ||||||||||||
2400psisg = 0 to 2400psi sealed gauge | - | 2400psisg | ||||||||||||
Accuracy (Non-Linearity & Hysteresis) | ||||||||||||||
A = <±0.25%/FS (standard) | - | A | ||||||||||||
B = <±0.1%/FS | - | B | ||||||||||||
Zero Temperature Compensation (TZS) | ||||||||||||||
4 = <±0.04%/FS/ºC | 4 | |||||||||||||
2 = <±0.02%/FS/ºC | 2 | |||||||||||||
1 = <±0.01%/FS/ºC | 1 | |||||||||||||
Process Connection | ||||||||||||||
A = G¼” Male DIN 3852 in UNS S31803 Duplex St/Steel | A | |||||||||||||
B = G¼” Male DIN 3852 in CA104 Marine Bronze | B | |||||||||||||
C = G¼” Male DIN 3852 in Titanium Alloy | C | |||||||||||||
D = ¼" NPT Male in UNS S31803 Duplex St/Steel | D | |||||||||||||
E = G¼" Male DIN 3852 in 316L St/Steel | E | |||||||||||||
F = G¼" Male DIN 3852 in Monel | F | |||||||||||||
O-Ring Material | ||||||||||||||
V = Viton (FKM) | V | |||||||||||||
N = Nitrile (NBR) | N | |||||||||||||
E = EPDM (Ethylene Propylene Diene Monomer) | E | |||||||||||||
C = Chemraz (Perfluoroelastomer/FFKM) | C | |||||||||||||
Mating Cable Assembly Length (in metres with flying leads at free end) | ||||||||||||||
00 = No Mating Assembly | - | 00 | ||||||||||||
01 = 1 metre | - | 01 | ||||||||||||
05 = 5 metres | - | 05 | ||||||||||||
Specials Code | ||||||||||||||
000 = No Special Requirements | - | 000 |
Downloads
CAD Model Files
Our 3D models are provided in STEP format and can be viewed using FreeCAD. Other formats can be provided on request.
The .zip file below contains a separate model for each product variant.
Why Applied Measurements?
- Suppliers of top quality strain gauge sensors and transducers to every corner of industry - UK and worldwide
- Over 100 years of expert transducer knowledge
- Our high quality products all come with a 3 year warranty
Popular Products
Platform Load Cell | Single Point Load Cell | 0-250g to 0-40kg | OBUG
0-250g to 0-40kgFrom £128Universal Load Cell | Universal S-Beam Force Sensor | DBBSM
0-1kg up to 0-30,000kgFrom £254Buy OnlineHandheld Load Cell Indicator | Digital Display | TR150
From £442Buy OnlineStrain Gauge Displacement Sensor | Linear Position Sensor | AML/SGD
0-5mm to 0-100mmFrom £425Buy Online