    Our last shipping day this year is Thursday 19th of December 2024 and our office and workshop will be closed for Christmas from Tuesday 24th of December 2024, re-opening on Thursday 2nd of January 2025. Orders placed in the web shop will be processed on our return. Thank you for your patience and Happy Christmas!

    LVDT Displacement Transducer | LVDT Position Sensor | AML/E

    Long Operating Life, Configurable and Value for Money

    At a Glance

    • Stroke Ranges: ±0.5mm to ±500mm
    • AC mV/V or DC Voltage / Current Output
    • Environmental Protection: IP55
    • Core-Only, Core + Extension,
    • Spring-Loaded & Rod-End Bearing Versions
    • Wide Range of Mechanical Configurations to Suit Your Specific Application
    • Fast and Simple Installation – With our wide variety of packaging formats.
    • Long Operating Life – No physical contact between the core and the coils.
    • Ideally Suited for OEM Applications
    • Let us do the Hard Work for You – We can provide you a wide range of supporting instrumentation.

    Description

    Applied Measurements AML/E series of standard LVDT displacement transducers are available with measuring ranges from ±0.5mm (0-1mm) up to ±500mm (0-1000mm).

    Constructed from stainless steel, they are sealed to IP54 and can be supplied in a variety of mechanical configurations including plain core-only, plain core & extension rod, guided core & extension rod, spring-loaded core & extension rod with ball-end or with guided core & spherical rod-end bearings.

    An AC mV/V output is available as standard, with a range of DC voltage signal output options also offered including 0-5Vdc, 0-10Vdc and ±2.5Vdc, as well as a 3-wire 4-20mA current output.

    The broad range of typical applications for the AML/E series include Industrial Automation, R&D, Manufacturing and Machine Building.

    Please see our full range of LVDT displacement transducers and position sensors.

    Technical Specifications

    CHARACTERISTICSAML/EAML/EJAML/EUAML/EU10AML/EIAML/EDUNITS
    Stroke Measurement Range:±0.5, ±2.5, ±5, ±10, ±12.5, ±15, ±25, ±50, ±75, ±100, ±125, ±150, ±175, ±200, ±250
    ±300, ±400, ±500, ±550 (maximum stroke is ±125 for Sprung Loaded Core & Extension - Option S)
    millimetres
    Signal Output:See Table Below0-5volt0-10volt4-20mA±2.5volt
    No. of Wires643334
    Supply Voltage (unregulated):2 to 5Vrms @ 1 to 5kHz10-24Vdc14-24Vdc14-24Vdc12Vdc regulated
    Supply Current:-35mA @ 15V35mA @ 15V35mA
    typ.
    35mA @ 12V
    Max. Loop Resistance:---300 @
    30V
    -ohms
    Max. Output Sink Current:-0.51-0.1milliamps
    Non-Linearity:<0.50±% Stroke Range
    Repeatability:<0.10±% Stroke Range
    Output Bandwidth:100100100100100100Hz
    Output Ripple:-30mV max.30mV max.0.1% @
    20mA
    30mV max.
    Operating Temperature Range:AML/E & EJ: -30 to +85 Standard / -30 to +150 and -30 to +200 Optional
    -20 to +85 on DC/DC models / 0 to +70 for in-line conditioner (where fitted)
    °C
    Zero Temperature Coefficient:<0.020<0.010±%Stroke Range/°C
    Span Temperature Coefficient:<0.020<0.030±%Stroke Range/°C
    Vibration Resistance:20g up to 2kHz
    Shock Resistance:1000g for 10milliseconds
    Construction Materials:Body & Extension Rod: 303 St/Steel, Core: 416 St/Steel, Cable Gland: Nickel-Plated Brass,
    Spring: 316 St/Steel, Rod-End Bearings: Mild Steel
    Electrical Connection:2 metre screened PVC cable* (*High-Temp Version = PTFE).
    Axial or radial exit available - see ordering codes for full details.
    Environmental Sealing:IP55
    Note: On DC output version (0Vdc / 4mA) is given with the core in the extended / outwards position. This can be reversed if required, please request
    Option Y on your order.

    Product Dimensions

    AC Output, Plain Core, Core & Extension and Rod Ends Dimensions Table
    Standard
    (Plain Core)
    Option X&G
    (Core + Extension)
    Option R
    (Rod End Bearings)
    Standard, X&G, R
    Stroke
    (mm)
    Body Length
    (mm)
    Core Length
    (mm)
    Null Position
    (mm)
    Body Length
    (mm)
    Body Length
    (mm)
    "L"
    (mm)
    Sensitivity @ 3kHz
    with 50K Load
    (mV/V FRO)
    Null
    (mV)
    Primary Resistance
    (ohms)
    Secondary Resistance
    (mm)
    ±0.5401412.3406513317520401800
    ±2.5421415.842701381405130740
    ±58329308395163135548108
    ±1083353783110178270570170
    ±12.510235441021171851955120190
    ±151305058130140208246590190
    ±2517076791701852532255130210
    ±502561151212562733412605200270
    ±7533013815633034541339020260460
    ±1003871401803873974652405150150
    ±1254451522084454555232605180320
    ±1505221652505225326002305210290
    ±1755731602645735836512602230360
    ±20063818530663864871628510250430
    ±25076017034876077083831010290560
    ±3008601854048608709382705690770
    ±4001110250544111011201188440204501010
    ±5001360314670136013701438475105501530
    ±5501360190670136013701438345105501530
    • AML-E Standard LVDT Displacement Transducer AC Version Plain Core Outline
      AML-E Standard LVDT Displacement Transducer AC Version Plain Core Outline
    • AML-E Standard LVDT Displacement Transducer AC Version Core + Extension (X&G) Outline
      AML-E Standard LVDT Displacement Transducer AC Version Core + Extension (X&G) Outline
    • AML-E Standard LVDT Displacement Transducer AC Version Rod End Bearings (R) Outline
      AML-E Standard LVDT Displacement Transducer AC Version Rod End Bearings (R) Outline

    Plain Core AML-E Standard AC Version Options: A = axial cable exit; C = radial cable exit; J = 4-wire device; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable.

    Option X & G AML-E AC Version with Core + Extension Options: A = axial cable exit; C = radial cable exit; J = 4-wire device; X = extension with plain core; G = guided core & extension;  H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable.

    Option R AML-E AC Version with M6 Rod End Bearings Options: R = radial cable ONLY; J = 4-wire device; X = extension with plain core; G = guided core & extension;  H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; HR = high temperature 150°C with PTFE cable stainless steel rod end bearings.

    Axial cable exit is NOT available with rod ends unless rod end is on the extension only.

    AC Output, Sprung-Loaded Dimensions Table
    Stroke
    (mm)
    Body Length
    (mm)
    Sensitivity @ 3kHz
    with 50K Load
    (mV/V FRO)
    Null
    (mV)
    Primary Resistance
    (ohms)
    Secondary Resistance
    (ohms)
    Spring Rate
    (N/mm)
    ±0.560160204018000.3886
    ±2.56716551307400.2914
    ±51081305481080.1166
    ±101081465701700.1166
    ±12.512718551201900.0897
    ±151552205901900.0729
    ±2519520651302100.0555
    ±5028118252002700.0389
    ±75355260202604600.0291
    ±100355350202604600.0291
    ±12541217851452300.0253
    • AML-E Standard LVDT Displacement Transducer AC Version Sprung-Loaded (S) Outline
      AML-E Standard LVDT Displacement Transducer AC Version Sprung-Loaded (S) Outline

    Option S AML-E AC Version Sprung Loaded Options: A = axial cable exit; C = radial cable exit; H = High Temperature 150°C, J = 4-wire device; K = extension rod wiper.

    VH high-temperature 200°C options are NOT available on sprung loaded.

    DC Output Dimensions Table
    StandardOption X&GOption ROption S
    Stroke
    (mm)
    Body Length (mm)Core Length (mm)Null Position (mm)Body Length (mm)Body Length (mm)"L" (mm)Body Length (mm)Spring Rate (N/mm)
    ±0.5821412.382921601000.4318
    ±2.5851415.8851001681070.2914
    ±512329301231332011480.1295
    ±1013035371301432111480.1295
    ±12.514235441421522201670.0933
    ±1517050581701802481950.0833
    ±2521076792102202882350.0583
    ±502961151212963063743210.0376
    ±753701381563703804483950.0291
    ±1004271401804274375053950.0291
    ±1254851522084854955634700.0253
    ±150562165250562572640n/an/a
    ±175613160264613623691n/an/a
    ±200678185306678688756n/an/a
    ±250800170348800810878n/an/a
    ±300900185404900910978n/an/a
    ±4001150250544115011601228n/an/a
    ±5001400314670140014101478n/an/a
    ±5501400190670140014101478n/an/a
    • AML-E Standard LVDT Displacement Transducer DC Version Plain Core Outline
      AML-E Standard LVDT Displacement Transducer DC Version Plain Core Outline
    • AML-E Standard LVDT Displacement Transducer DC Version Core + Extension (X&G) Outline
      AML-E Standard LVDT Displacement Transducer DC Version Core + Extension (X&G) Outline
    • AML-E Standard LVDT Displacement Transducer DC Version with M6 Rod End Bearings (R) Outline
      AML-E Standard LVDT Displacement Transducer DC Version with M6 Rod End Bearings (R) Outline
    • AML-E Standard LVDT Displacement Transducer DC Version Sprung-Loaded (S) Outline
      AML-E Standard LVDT Displacement Transducer DC Version Sprung-Loaded (S) Outline

    Plain Core AML-E Standard DC Version Options: A = axial cable exit; C = radial cable exit; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA).

    H and VH high-temperature options are not available.

    Option X & G AML-E Standard DC Version with Core & Extension Options: A = axial cable exit; C = radial cable exit; G = guided core & extension; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA).

    H and VH high-temperature options are not available.

    Option R AML-E Standard DC Version with M6 Rod End Bearings Options: C = radial cable exit; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA).

    H and VH high-temperature options are not available.

    Option S AML-E Standard DC Version Sprung Loaded Options: A = axial cable exit; C = radial cable exit; K = extension rod wiper; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA).

    H and VH high-temperature options are not available.

    Ordering Codes & Options

    AML/EU10+/-500mm-X0A-02-000 (example code)AML/EU10+/-500mm-XOA-02-000
    Product Family
    AML/EAML/E
    Electrical Output
    Blank = 6-wire AC mV/VBlank
    J = 4-wire AC mV/VJ
    U = 0-5VdcU
    U10 = 0-10VdcU10
    I = 4-20mAI
    D = ±2.5Vdc (12Vdc regulated supply required)D
    Stroke Range
    +/-0.5mm (0-1mm) +/-0.5mm
    +/-2.5mm (0-5mm)+/-2.5mm
    +/-5mm (0-10mm)+/-5mm
    +/-10mm (0-20mm)+/-10mm
    +/-12.5mm+/-12.5mm
    +/-15mm (0-30mm)+/-15mm
    +/-25mm (0-50mm)+/-25mm
    +/-50mm (0-100mm)+/-50mm
    +/-75mm (0-150mm)+/-75mm
    +/-100mm (0-200mm)+/-100mm
    +/-125mm (0-250mm)+/-125mm
    +/-150mm (0-300mm)+/-150mm
    +/-175mm (0-350mm)+/-175mm
    +/-200mm (0-400mm)+/-200mm
    +/-250mm (0-500mm)+/-250mm
    +/-300mm (0-600mm)+/-300mm
    +/-400mm (0-800mm)+/-400mm
    +/-500mm (0-1000mm)+/-500mm
    +/-550mm (0-1100mm)+/-550mm
    Mechanical Configuration
    C = Core Only-C
    X = Un-Guided Core & Extension Rod-X
    G = Guided Core & Extension Rod-G
    S = Spring Loaded Core & Extension Rod with Ball-Tip (±125mm
    max range)
    -S
    R = Rod-End Bearings - Mild Steel (with Guided Core)-R
    H = 150ºC High Temperature Version AC only Core Only
    (DC output requires in-line amplifier @ 70°C max)
    -H
    HR = 150ºC High Temperature Version with Stainless Steel RodEnd Bearings-HR
    VH = 200ºC Very High Temperature, Core Only (AC output only)-VH
    VHR = 200ºC Very High Temperature + Stainless Steel Rod End
    Bearings with Guided Core (AC output only)
    -VHR
    HG = 150ºC High Temperature Version Guided Core &
    Extension Rod
    (DC output requires in-line amplifier @ 70°C max)
    -HG
    HS = 150ºC High Temperature Version Spring Loaded Core &
    Extension Rod with Ball-Tip (±125mm max range)
    (DC output requires in-line amplifier @ 70°C max)
    -HS
    HX = 150ºC High Temperature Version Un-Guided Core &
    Extension Rod
    (DC output requires in-line amplifier @ 70°C max)
    -HX
    VHX = 200ºC Very High Temperature, with PTFE cable, Unguided Core + Extension Rod (AC output only)-VHX
    VHG = 200ºC Very High Temperature, with PTFE cable, Guided Core + Extension Rod (AC output only)-VHG
    Output Direction (only affects DC output versions)
    0 = Zero with core extended, Full Scale with core retracted0
    Y = Full Scale with core extended, Zero with core retractedY
    Cable Exit Direction
    A = Axial (not available on rod end bearing version)A
    R = RadialR
    Cable Length (in metres)
    02 = 2 metres (standard)-02
    0,2 = 0.2 metres-0,2
    10 = 10 metres-10
    Specials Code
    000 = No Special Requirements-000
    Sales To Provide Specials Codes As Required

    Why Applied Measurements?

    • Suppliers of top quality strain gauge sensors and transducers to every corner of industry - UK and worldwide
    • Over 100 years of expert transducer knowledge
    • Our high quality products all come with a 3 year warranty
    BSI Assurance Mark ISO 9001:2015 FS677584
    We Are a Living Wage Employer
    Cyber Essentials Certified