LVDT Displacement Transducer | LVDT Position Sensor | AML/E

Long Operating Life, Configurable and Value for Money

AML-E Option R with Rod End Bearing
AML-E with Radial Cable Exit with Rod EndsAML-E with Axial Cable ExitAML-E Option S Spring Loaded with Ball EndAML-E Option C with Core Only
Lead Time
5 weeks
Prices From
£83
Accelerated delivery available
Quantity, OEM & educational discounts

At a Glance

  • Stroke Ranges: ±0.5mm to ±500mm
  • AC mV/V or DC Voltage / Current Output
  • Environmental Protection: IP54
  • Core-Only, Core + Extension,
  • Spring-Loaded & Rod-End Bearing Versions
  • Wide Range of Mechanical Configurations to Suit Your Specific Application
  • Fast and Simple Installation – With our wide variety of packaging formats.
  • Long Operating Life – No physical contact between the core and the coils.
  • Ideally Suited for OEM Applications
  • Let us do the Hard Work for You – We can provide you a wide range of supporting instrumentation.

Description

Applied Measurements AML/E series of standard LVDT displacement transducers are available with measuring ranges from ±0.5mm (0-1mm) up to ±500mm (0-1000mm).

Constructed from stainless steel, they are sealed to IP54 and can be supplied in a variety of mechanical configurations including plain core-only, plain core & extension rod, guided core & extension rod, spring-loaded core & extension rod with ball-end or with guided core & spherical rod-end bearings.

An AC mV/V output is available as standard, with a range of DC voltage signal output options also offered including 0-5Vdc, 0-10Vdc and ±2.5Vdc, as well as a 3-wire 4-20mA current output.

The broad range of typical applications for the AML/E series include Industrial Automation, R&D, Manufacturing and Machine Building.

Please see our full range of LVDT displacement transducers and position sensors.

Product Dimensions

AC Output, Plain Core, Core & Extension and Rod Ends Dimensions Table
 Standard
(Plain Core)
Option X&G
(Core + Extension)
Option R
(Rod End Bearings)
Standard, X&G, R
Stroke
(mm)
Body Length
(mm)
Core Length
(mm)
Null Position
(mm)
Body Length
(mm)
Body Length
(mm)
"L"
(mm)
Sensitivity @ 3kHz
with 50K Load
(mV/V FRO)
Null
(mV)
Primary Resistance
(ohms)
Secondary Resistance
(mm)
±0.5401412.3406513317520401800
±2.5421415.842701381405130740
±58329308395163135548108
±1083353783110178270570170
±12.510235441021171851955120190
±151305058130140208246590190
±2517076791701852532255130210
±502561151212562733412605200270
±7533013815633034541339020260460
±1003871401803873974652405150150
±1254451522084454555232605180320
±1505221652505225326002305210290
±1755731602645735836512602230360
±20063818530663864871628510250430
±25076017034876077083831010290560
±3008601854048608709382705690770
±4001110250544111011201188440204501010
±5001360314670136013701438475105501530
±5501360190670136013701438345105501530
  • AML-E Standard LVDT Displacement Transducer AC Version Plain Core Outline
    AML-E Standard LVDT Displacement Transducer AC Version Plain Core Outline
  • AML-E Standard LVDT Displacement Transducer AC Version Core + Extension (X&G) Outline
    AML-E Standard LVDT Displacement Transducer AC Version Core + Extension (X&G) Outline
  • AML-E Standard LVDT Displacement Transducer AC Version Rod End Bearings (R) Outline
    AML-E Standard LVDT Displacement Transducer AC Version Rod End Bearings (R) Outline

Plain Core AML-E Standard AC Version Options: A = axial cable exit; C = radial cable exit; J = 4-wire device; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; L = increased linearity ±0.25%.

Option X & G AML-E AC Version with Core + Extension Options: A = axial cable exit; C = radial cable exit; J = 4-wire device; X = extension with plain core; G = guided core & extension;  H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; L = increased linearity ±0.25%.

Option R AML-E AC Version with M6 Rod End Bearings Options: R = radial cable ONLY; J = 4-wire device; X = extension with plain core; G = guided core & extension;  H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; HR = high temperature 150°C with PTFE cable stainless steel rod end bearings; L = increased linearity ±0.25%.

Axial cable exit is NOT available with rod ends unless rod end is on the extension only.

AC Output, Sprung-Loaded Dimensions Table
Stroke
(mm)
Body Length
(mm)
Sensitivity @ 3kHz
with 50K Load
(mV/V FRO)
Null
(mV)
Primary Resistance
(ohms)
Secondary Resistance
(ohms)
Spring Rate
(N/mm)
±0.560160204018000.3886
±2.56716551307400.2914
±51081305481080.1166
±101081465701700.1166
±12.512718551201900.0897
±151552205901900.0729
±2519520651302100.0555
±5028118252002700.0389
±75355260202604600.0291
±100355350202604600.0291
±12541217851452300.0253
  • AML-E Standard LVDT Displacement Transducer AC Version Sprung-Loaded (S) Outline
    AML-E Standard LVDT Displacement Transducer AC Version Sprung-Loaded (S) Outline

Option S AML-E AC Version Sprung Loaded Options: A = axial cable exit; C = radial cable exit; J = 4-wire device; K = extension rod wiper; H = high temperature 150°C with PTFE cable; VH = very high temperature 200°C with PTFE cable; L = increased linearity ±0.25%.

DC Output Dimensions Table
 StandardOption X&GOption ROption S
Stroke
(mm)
Body Length (mm)Core Length (mm)Null Position (mm)Body Length (mm)Body Length (mm)"L" (mm)Body Length (mm)Spring Rate (N/mm)
±0.5821412.382921601000.4318
±2.5851415.8851001681070.2914
±512329301231332011480.1295
±1013035371301432111480.1295
±12.514235441421522201670.0933
±1517050581701802481950.0833
±2521076792102202882350.0583
±502961151212963063743210.0376
±753701381563703804483950.0291
±1004271401804274375053950.0291
±1254851522084854955634700.0253
±150562165250562572640n/an/a
±175613160264613623691n/an/a
±200678185306678688756n/an/a
±250800170348800810878n/an/a
±300900185404900910978n/an/a
±4001150250544115011601228n/an/a
±5001400314670140014101478n/an/a
±5501400190670140014101478n/an/a
  • AML-E Standard LVDT Displacement Transducer DC Version Plain Core Outline
    AML-E Standard LVDT Displacement Transducer DC Version Plain Core Outline
  • AML-E Standard LVDT Displacement Transducer DC Version Core + Extension (X&G) Outline
    AML-E Standard LVDT Displacement Transducer DC Version Core + Extension (X&G) Outline
  • AML-E Standard LVDT Displacement Transducer DC Version with M6 Rod End Bearings (R) Outline
    AML-E Standard LVDT Displacement Transducer DC Version with M6 Rod End Bearings (R) Outline
  • AML-E Standard LVDT Displacement Transducer DC Version Sprung-Loaded (S) Outline
    AML-E Standard LVDT Displacement Transducer DC Version Sprung-Loaded (S) Outline

Plain Core AML-E Standard DC Version Options: A = axial cable exit; C = radial cable exit; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA); L = increased linearity ±0.25%.

H and VH high temperature options are not available.

Option X & G AML-E Standard DC Version with Core & Extension Options: A = axial cable exit; C = radial cable exit; G = guided core & extension; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA); L = increased linearity ±0.25%.

H and VH high temperature options are not available.

Option R AML-E Standard DC Version with M6 Rod End Bearings Options: C = radial cable exit; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA); L = increased linearity ±0.25%.

H and VH high-temperature options are not available.

Option S AML-E Standard DC Version Sprung Loaded Options: A = axial cable exit; C = radial cable exit; K = extension rod wiper; I = 4-20mA output; U = 0-5V output; U-10 = 0-10V output; D = DC bipolar output; Y = reverse output (eg. 4mA fully in instead of default 20mA); L = increased linearity ±0.25%.

H and VH high-temperature options are not available.

Instant Price & Part Code Builder

You can now buy this product in our online shop. Alternatively, you can find the ordering code, price* and lead time below.

AML-E Option R with Rod End Bearing

Price*:

*Please note: The prices shown are valid in the UK only and do not include carriage charges. For overseas pricing please contact a member of our sales team or your local distributor.

Lead Time:

Part Code:

Send me this information

    Enter your email address to receive a copy of this information

    Interested in this product? Send us an enquiry...

      Why Applied Measurements?

      • Suppliers of top quality strain gauge sensors and transducers to every corner of industry - UK and worldwide
      • Over 100 years of expert transducer knowledge
      • Our high quality products all come with a 3 year warranty