Last updated: 30th April 2026
Due to our policy on ongoing development, dimensions and specifications may change without notice.

Micro Button Load Cell | CDFT

Sub-Miniature, Accurate and Measuring Only 2.9mm in Height!

  • Lead Time: 5 weeks
  • Buy online: https://appmeas.co.uk/shop/load-cells/cdft/
    Buy Online
micro button load cell cdf

At a Glance

  • Capacities: 0-25N up to 0-250N
  • Ø9mm and 2.9mm Height
  • Environmental Protection: IP53
  • Accuracy: <±0.25%/RC
  • Integral Load Button
  • Very Compact – At Ø9mm x 2.9mm height it easily fits into the smallest of spaces.
  • Save on Installation Time – Ideal for retrofitting into existing designs.
  • Optimum Performance Guaranteed – With its integral load button.
  • Ideal for Compression Measurement with Limited Space.

Description

Applied Measurements CDFT micro button load cell is designed for compression measurement applications where the absolute minimum of space is available for transducer mounting.

With capacities from 25N to 250N available and measuring just 9mm in diameter and 2.9mm in height, the CDFT is the smallest standard button load cell that we offer.  If you need to measure lower or higher forces, the CDFM3 miniature button load cell is available in capacities from 0-100N right up 0-20kN and is slightly larger at 30mm diameter and 12mm in height.

Applied Measurements CDFT micro button load cell is ideal for retro-fitment and is ideal to use in robotics and effectors, hoist and winch loads, micro-component assembly tools and machinery, keyboard button and telephone control and mechanical switches.

The CDFT has an in-line temperature compensation module which measures a slimline 12.7mm diameter and 69mm long. The module is the aluminium cylinder in the above images and can optionally be positioned further away from the CDFT. The module’s output cable is a Ø3.3mm black PVC type which will carry the measurement signal to the your monitoring or control equipment.

We can supply the CDFT micro button load cell with a wide range of transducer instrumentation such as digital indicators, intuitive panel meters, handheld digital readouts and wireless telemetry systems.

Technical Specifications

Rated CapacityN0-25, 0-50, 0-100, 0-200, 0-250
Operating ModesCompression Only
Sensitivity (RO)mV/V (±30% typical)25N = 0.5
50N = 1.0
100N = 2.0
200N = 2.0
250N = 2.0
Zero Balance/Offset±%/Rated Output<1.0
Non-Linearity±%/Rated Output (BFSL)<0.25
Hysteresis%/Rated Output<0.25
Repeatability%/Rated Output<0.1
Temperature Effect on Zero±%/Rated Output/ ˚C<0.01
Temperature Effect on Sensitivity±%/Applied Load/ ˚C<0.02
Input ResistanceOhms1000 nominal
Output ResistanceOhms1000 nominal
Insulation ResistanceMegohms>5000 @ 50Vdc
Excitation VoltageVolts AC or DC5 recommended (2-10 acceptable)
Operating Temperature Range˚C-40 to +125 (cell only)
Compensated Temperature Range˚C0 to +100
Storage Temperature Range˚C-40 to +125
Safe Overload% of Rated Capacity150
Ultimate Overload% of Rated Capacity300
Deflection @ Rated Capacitymm<0.02
Fundamental Resonant Frequency*kHz>4
IP Rating (Environmental Protection)IP53
Weightgrams~2 (excluding cable)
Fatigue Life108 cycles typical (109 cycles on fatigue-rated version)
Cable Length (as standard)metres2 (1.5m to compensation module + 0.5m tail)
Cable TypeØ1.35 screened PTFE from cell, Ø3.3 screened PVC from
compensation module
Construction MaterialsStainless Steel
Resolution1 part in 250,000 (with appropriate instrumentation)
*The resonant frequency is calculated with the body of the load cell attached to a large plate, ensuring that only the sensing element oscillates.
This is vital to achieve the highest natural frequency and subsequent frequency response.

Product Dimensions

Micro button load cell CDFT schematic drawing
Schematic drawing of the CDFT and in-line compensation module

Wiring Details

WireDesignation
Red+ve excitation
Blue-ve excitation
Green+ve signal
Yellow-ve signal
ScreenTo ground - not connected to load cell body

Ordering Codes & Options

Core ProductCapacity (inc Engineering Units)Cable Length (m)Specials CodeExample Result
CDFT25N002000CDFT-25N-002-000
CDFT50N002000CDFT-50N-002-000
CDFT100N002000CDFT-100N-002-000
CDFT200N002000CDFT-200N-002-000
CDFT250N002000CDFT-250N-002-000