At a Glance
- Extremely Compact
- RS485 Output
- Available Protocols: ASCII, MantraBUS II, MODBUS RTU, MantraCAN (J1939)
- High Speed: 500 Readings/Second max
- Available with In-Line Enclosure for Mounting on Load Cell Cable
- Delivers a RS485 Digital Output for Easy PC or PLC Connection
- Only Ø19mm – Ideal for Mounting Inside a Sensor
- Fast & Simple Installation – Using a Single M2 Screw
- Optimum Performance Guaranteed with its 1 Part in 200,000 (18bit) Resolution
- Improved Transducer Results with Digital Linearisation and Temperature Compensation
- Harsh Environment Option – Total Dust & Low Pressure Water Jet Protected Enclosure
Description
The DCell is a miniature load cell digitiser / strain gauge digitiser designed to work with any strain gauge-based transducers to provide a high stability digital RS485 output.
The load cell digitiser’s small size of just 20mm diameter and 5mm high allows it to fit inside the body of the majority of load cells and strain gauge sensors, conveniently mounted using a single M2 screw. Available output protocols include ASCII, MANTRABUS II, MODBUS RTU or MantraCAN (J1939).
The DCell load cell digitiser is capable of operating from a DC voltage ranging from 5.4V to 18V. The input is reverse polarity protected and requires a minimum operating current of 60mA.
The strain gauge digitiser offers high speed conversion rates up to 500 readings/second, very high stability-up to 6000 divisions OIML and Baud rates up to 230,400.
PC-based calibration can be direct from the sensor or mV/V based and includes linearization and temperature compensation.
Other third party products like the DLCSCOP can be easily substituted by one of our DLCSMCAN DCells and will deliver matching performance and longevity.
Part numbers for DCell series include
DLCHASC, DLCHMAN, DLCHMOD, DLCHMCAN, DLCSASC, DLCSMAN, DLCSMOD and DLCSMCAN
Technical Specifications
DCELL High Stability
Parameter | Min | Typical | Max | Units |
---|---|---|---|---|
Bridge Excitation | 4.5 | 5 | 5.25 | VDC |
Sensor Impedance up to 18V Supply | 320 | 350 | 5,000 | Ohms** |
Sensor Impedance up to 12V Supply | 120 | 350 | 5,000 | Ohms** |
Bridge Sensitivity | -3 | +3 | mV/V | |
Offset Temperature Stability | 1 | 4 | ppm/C | |
Gain Temperature Stability | 3 | 5 | ppm/C | |
Offset Stability with Time | 0.002 | 0.008 | %FR | |
Gain Stability with Time | 30 | ppm of FR/1st Year | ||
Non Linearity | 0.0005 | 0.0025 | %FR | |
Internal Resolution | 16 Million | Counts/Divisions | ||
Resolution @ 1Hz (Noise Stable) * | 200,000 | Counts/Divisions | ||
Resolution @ 10Hz (Noise Stable) * | 120,000 | Counts/Divisions | ||
Resolution @ 100Hz (Noise Stable) * | 50,000 | Counts/Divisions | ||
Resolution @ 500Hz (Noise Stable) * | 18,000 | Counts/Divisions | ||
Optional Temperature Measurement Resolution | 0.1 | ºC | ||
Optional Temperature Measurement Accuracy | 1 | ºC | ||
Notes: From original offset at any time. *Stability over 100 second period. **Subject to supply voltage. See Electrical Specification | ||||
Electrical | ||||
Power Supply Voltage | 5.4 | 12 | 18 | V dc |
Power Supply Noise/Ripple | 100 | mV ac pk-pk | ||
Power Supply Current (350R Bridge) | 45 | 60 | mA | |
Power @ 10V Supply (350R Bridge) | 350 | mW | ||
Sensor Impedance up to 18v Supply | 320 | 350 | 5,000 | ohms |
Sensor Impedance up to 12v Supply | 120 | 350 | 5,000 | ohms |
Excitation System | 4 wire | |||
Environmental | ||||
Operating Temperature Range | -40 | 85 | °C | |
Operating Temperature Range for OIML 6000d | -10 | 55 | °C | |
Storage Temperature | -40 | 85 | °C | |
Humidity | 0 | 95 | %RH on Condensing | |
Communications | ||||
RS485 Data Rate | 2,400 | 230k | Baud | |
CAN Bit Rate | 10k | 1M | Bits/Sec | |
Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec | ||||
Protocols | ASCII, MANTRABUS II, Modbus RTU or MantraCAN (J1939). | |||
Please Note: MantraCAN products will only work with Microsoft operating systems up to and including Windows 10. |
DCELL Industrial Stability
Parameter | Min | Typical | Max | Units |
---|---|---|---|---|
Excitation | 4.5 | 5 | 5.25 | VDC |
Sensor Impedance up to 18v Supply | 320 | 350 | 5,000 | Ohms** |
Sensor Impedance up to 12v Supply | 120 | 350 | 5,000 | Ohms** |
Bridge Sensitivity | -3 | +3 | mV/V | |
Offset Temperature Stability | 5 | 10 | ppm/C | |
Gain Temperature Stability | 30 | 50 | ppm/C | |
Offset Stability with Time | 0.0035 | 0.016 | %FR „] | |
Gain Stability with Time | 300 | ppm of FR /1st Year | ||
Non Linearity | 0.0005 | 0.0025 | % FR | |
Internal Resolution | 16 Million | Counts/Divisions | ||
Resolution @ 1Hz (Noise Stable) * | 66,000 | Counts/Divisions | ||
Resolution @ 10Hz (Noise Stable) * | 40,000 | Counts/Divisions | ||
Resolution @ 100Hz (Noise Stable) * | 10,000 | Counts/Divisions | ||
Resolution @ 500Hz (Noise Stable) * | 5,000 | Counts/Divisions | ||
Optional Temperature Measurement Resolution | 0.1 | ºC | ||
Optional Temperature Measurement Accuracy | 1 | ºC | ||
Notes: From original offset at any time. *Stability over 100 second period. ** Subject to supply voltage. See Electrical Specification | ||||
Electrical | ||||
Power Supply Voltage | 5.6 | 12 | 18 | V dc |
Power Supply Noise/Ripple | 100 | mV ac pk-pk | ||
Power Supply Current (350R Bridge) | 45 | 60 | mA | |
Power @ 10V Supply (350R Bridge) | 350 | mW | ||
Sensor Impedance up to 18v Supply | 320 | 350 | 5,000 | ohms |
Sensor Impedance up to 12v Supply | 120 | 350 | 5,000 | ohms |
Excitation System | 4 wire | |||
Environmental | ||||
Operating temperature range | -40 | 85 | °C | |
Storage temperature | -40 | 85 | °C | |
Humidity | 0 | 95 | %RH Non Condensing | |
Communication | ||||
RS485 Data Rate | 2,400 | 230k | Baud | |
CAN Bit Rate | 10k | 1M | Bits/Sec | |
Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec | ||||
Protocols | ASCII, MANTRABUS II, Modbus RTU or MantraCAN (J1939). Please Note: MantraCAN products will only work with Microsoft operating systems up to and including Windows 10. | |||
Support Modules | Instrument Explorer Software free PC software, RS232 - RS485 Convertor, DCell Evaluation Kits | |||
CE Environmental Approvals | European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC |
Product Dimensions
Dcell Enclosure Dimensions
Ordering Codes & Options
DLCHASC (example code) | DLC | H | ASC | |
---|---|---|---|---|
Model | ||||
DLC | DLC | |||
Stability | ||||
High | H | |||
Industrial | S | |||
Protocol | ||||
ASCII | ASC | In Cell ASCII Protocol | ||
MANTRABUS | MAN | In Cell MANTRABUS Protocol | ||
MODBUS | MOD | In Cell MODBUS Protocol | ||
MantraCAN (J1939) | MCAN | In Cell MantraCAN (J1939) Protocol | ||
Options | Details | |||
ILE | In-Line Housing for Load Cell Amplifiers & Digital Converters (*Ex Works) | |||
DS485DIS | Display Module with RS485 Input | |||
EVAL KIT 485 | Evaluation Kit RS485 (*Ex Works) | |||
EVAL KIT CAN | Evaluation Kit for CAN (*Ex Works) | |||
DTEMP | Digital Temperature Sensor Module for Wiring to DCell/DSC |