Strain Gauge Load Cell Digitiser Card | RS232 | RS485 | DSC

Compact, High-Speed Load Cell Converter for In-Line Mounting

  • Lead Time: 3 days
dsc strain gauge load cell converter

At a Glance

  • Extremely Compact
  • RS232 & RS485 Output Versions
  • Available Protocols: ASCII, MantraBUS II, Modbus RTU, MantraCAN (J1939)
  • High Speed: 500 Readings/Second max
  • Available with In-Line Enclosure for Mounting on Load Cell Cable
  • Delivers a Digital Output for Easy PC or PLC Connection
  • Fast & Simple Fitting Thanks to its OEM PCB Format
  • Optimum Performance Guaranteed with its 1 Part in 200,000 (18bit) Resolution
  • Improved Transducer Results with Digital Linearisation and Temperature Compensation
  • Harsh Environment Option – Total Dust & Low Pressure Water Jet Protected Enclosure

Description

The DSC is a load cell digitiser that takes a strain gauge input and converts it to an RS232 or RS485 digital signal.  The strain gauge converter is designed for use with a variety of transducers including load cells, pressure transducers, torque sensors and displacement transducers.

The DSC strain gauge load cell digitiser offers high accuracy, high-speed signal conversion with digital linearisation and temperature compensation to improve transducer far beyond its normal performance level.  Available protocols are; ASCII, MODBUS and MantraCAN (J1939).

Designed to be mounted in-line with the transducer, the load cell converter is available pre-mounted in an IP65 enclosure.  There are two enclosure options; the DSJ1 which holds a single load cell converter, and the DSJ4 which holds four load cell converters.  The DSJ4 requires RS485 output versions of the load cell converter as this is the only type suitable for ‘daisy-chaining’ on a single bus.

The PC-based calibration of the strain gauge converter can be performed directly from the sensor output signal, or as an mV/V sensitivity entry for ultimate flexibility.

Other strain gauge converter features include very high resolution of up to 1:200,000, high speed output at up to 500 updates/second and programmable dynamic filtering.

Technical Specifications

DSCH High Stability

ParameterMinTypicalMaxUnits
Bridge Excitation4.555.25VDC
Sensor Impedance up to 18v Supply3203505,000Ohms**
Sensor Impedance up to 12v Supply1203505,000Ohms**
Bridge Sensitivity-3+3mV/V
Offset Temperature Stability14ppm/C
Gain Temperature Stability35ppm/C
Offset Stability with Time0.0020.008%FR
Gain Stability with Time30ppm of FR/1st Year
Non Linearity0.00050.0025%FR
Resolution @ 1Hz (Noise Stable) *200,000Counts/Divisions
Resolution @ 10Hz (Noise Stable) *120,000Counts/Divisions
Resolution @ 100Hz (Noise Stable) *50,000Counts/Divisions
Resolution @ 500Hz (Noise Stable) *18,000Counts/Divisions
Optional Temperature Measurement Resolution0.1ºC
Optional Temperature Measurement Accuracy1ºC
Notes: From original offset at any time. *Stability over 100 second period. **Subject to supply voltage. See Electrical Specification
Electrical
Power Supply Voltage5.61218V dc
Power Supply Noise/Ripple100mV ac pk-pk
Power Supply Current (350R Bridge)4560mA
Power @ 10V Supply (350R Bridge)350mW
Sensor Impedance up to 18v Supply3203505,000ohms
Sensor Impedance up to 12v Supply1203505,000ohms
Excitation System 4 wire4 wire
Environmental
Operating Temperature Range-4085°C
Operating Temperature Range for OIML 6000d-1055°C
Storage Temperature-4085°C
Humidity095%RH on Condensing
Communications
RS485 Data Rate2,400230kBaud
CAN Bit Rate10k1MBits/Sec
Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec
Protocols
Please Note: MantraCAN products will only work with Microsoft operating systems up to and including Windows 10.

DSCS Industrial Stability

ParameterMinTypicalMaxUnits
Bridge Excitation4.555.25VDC
Bridge Impedance3203505,000Ohms
Sensor Impedance up to 18v Supply3203505,000Ohms**
Sensor Impedance up to 12v Supply1203505,000Ohms**
Bridge Sensitivity-3+3mV/V
Offset Temperature Stability510ppm/C
Gain Temperature Stability3050ppm/C
Offset Stability with Time0.00350.016%FR „]
Gain Stability with Time300ppm of FR /1st Year
Non Linearity0.00050.0025% FR
Internal Resolution16 MillionCounts/Divisions
Resolution @ 1Hz (Noise Stable) *66,000Counts/Divisions
Resolution @ 10Hz (Noise Stable) *40,000Counts/Divisions
Resolution @ 100Hz (Noise Stable) *10,000Counts/Divisions
Resolution @ 500Hz (Noise Stable) *5,000Counts/Divisions
Optional Temperature Measurement Resolution0.1°C
Optional Temperature Measurement Accuracy1°C
Notes: From original offset at any time. *Stability over 100 second period. **Subject to supply voltage. See Electrical Specification
Electrical
Power Supply Voltage5.61218V dc
Power Supply Noise/Ripple100mV ac pk-pk
Power Supply Current (350R Bridge)4560mA
Power @ 10V Supply (350R Bridge)350mW
Sensor Impedance up to 18v Supply3203505,000ohms
Sensor Impedance up to 12v Supply1203505,000ohms
Excitation System4 wire
Environmental
Operating temperature range-4085°C
Storage temperature-4085°C
Humidity095%RH Non Condensing
Communications
RS485 Data Rate2,400230kBaud
CAN Bit Rate10k1MBits/Sec
Note: Update speeds are selectable to 1, 2, 5, 10, 20, 50, 60, 100, 200, 300, 500 Samples/Sec
Protocols
ASCII, MANTRABUS II, Modbus RTU or MantraCAN (J1939).
Please Note: MantraCAN products will only work with Microsoft operating systems up to and including Windows 10.
Support ModulesInstrument Explorer Software free PC software, RS232 - RS485 Convertor, DCell Evaluation Kits
CE Environmental ApprovalsEuropean EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC

Product Dimensions (mm)

DSC Strain Gauge Load Cell Digitiser Outline Drawing

Dimensions – Enclosure with 1 DSC Card – DSJ1

DSJ1 Enclosure Outline

Dimensions – Enclosure with 4 DSC Cards – DSJ4

DSJ4 Enclosure Outline

Ordering Codes & Options

DSCH2ASC (example code)DSCH2ASC
Model
DSCDSC
Stability
HighH
IndustrialS
Output
RS2322
RS4854
MantraCAN (J1939)Leave Blank
Protocol
ASCIIASC
MANTRABUSMAN
MODBUSMOD
MantraCAN (J1939)MCAN