At a Glance
- For use with all T24 Acquisition Modules
- Single Channel
- Holds 2x ‘D’ Batteries – up to 5 Years Life!
- IP67 Rated ABS Enclosure
- Field Connection Terminals
- Ideal for BOTH Indoor and Outdoor Applications
- Suited to TOUGH Industrial Environments
- Immersion Protected up to 1 metre for 30 mins
- Fast and Simple Installation – Screw Type Wiring Terminals
- Fantastic Transmission Range – Up to 800 metres!
Description
The T24-ACM industrial wireless transmitter module provides a tough and durable mounting enclosure suitable for any of the T24 telemetry acquisition modules; T24-SA, T24-SAf, T24-IA & T24-VA.
The T24-ACM incorporates a mounting PCB for your chosen T24 acquisition module (not included), simple screw-type wiring terminals, a battery holder for 2x ‘D’ size batteries and an external antenna to provide improved transmission range of up to 800 metres. You will need to purchase the external ‘e’ suffix version of the acquisition module to utilise this antenna.
The industrial wireless transmitter module enclosure is rated to IP67 making it suitable for use in many tough industrial and outdoor environments.
Battery life using 2x ‘D’ size cells is up to 5 years depending on the configuration of your system.
Please contact our expert sales team using the quick enquiry on the right, call us on +44 (0) 1189 817339, or send an email to info@appmeas.co.uk and we will be happy to assist you with your enquiry.
Technical Specifications
Radio | Min | Typical | Max | Units |
---|---|---|---|---|
Licence | Licence Exempt | |||
Modulation Method | MS (QPSK) | |||
Radio Type | Transceiver (2 way) | |||
Data Rate | 250 | K bits / second | ||
Radio Frequency | 2.4 | 2.4835 | GHz | |
Power | 10 | mW | ||
Power Supply | 2 x D Cells or 5-18Vdc | |||
Range* | 800 | Metres | ||
Channels (DSSS) | 15 | |||
*Tests conducted in an open field site with the transmitter at the top of a 3m pole. The receiver was mounted 1.5m off the ground. |
Product Dimensions
Ordering Codes & Options
Input Modules (Determined by Order Code) | |
---|---|
T24-ACM-SA | Strain Gauge (load cells, force transducers, pressure sensors, etc.). |
T24-ACM-SAf | Fast Strain Gauge (2kHz version of the above). |
T24-ACM-IA | Current (4-20mA or 0-20mA input). |
T24-ACM-VA | Voltage (0-5Vdc, 0-10Vdc, 0-4.5Vdc, 1-5Vdc, 1-6Vdc, etc.). |
T24-ACM-TA | Temperature (for PT100 type 385 sensors). |
T24-ACM-PA | Pulse (Outputs in rpm, Hz, and time, actual pulse counting and measuring the period between pulses). |
T24-ACM-RA | Potentiometer (for any potentiometer-based sensor with a resistance). |