Barometric Pressure Sensor | Atmospheric Pressure Sensor | Pi600B

Accurate, Adaptable, for Terrestrial Ambient Pressure Measurements

  • This product has been discontinued
  • The current equivalent is the Barometric Pressure Sensor | Pa600B
Pi600B Atmospheric Barometric Pressure Sensor

At a Glance

  • Range: 750-1250mbar Absolute
  • Outputs: Voltage or Current (mA)
  • Environmental Protection: IP65
  • Accuracy: <±0.25%/FS (0.1% option)
  • Optional IP66 or IP68 Sealing
  • Ideal for Weather Stations and Meteorological Applications 
  • Marine and Offshore Submersible Versions Available
  • Protected from Low Pressure Water Jets as Standard
  • Customised Versions Available to Suit Your Application
  • Fast and Simple Setup with Custom Process Connections

Description

The Pi600B barometric pressure sensor / atmospheric pressure sensor is based on the standard Pi600 industrial pressure transducer and has a sensing range from 750 to 1250 millibar absolute.  It is designed specifically for the measurement of barometric pressure / atmospheric pressure.

The Pi600B barometric atmospheric pressure sensor is suited to any common terrestrial ambient pressure measurement application such as weather stations, process reference and many general meteorological applications.

The Pi600B barometric pressure sensor series offers a wide choice of electrical outputs from it’s ASIC-based amplifier circuit, these include 4-20mA, 0-5Vdc, 0-10Vdc and 1-6Vdc, as well as a ratiometric 0.5-4.5Vdc signal that requires a 5Vdc supply to suit most data loggers.

A G¼” male process connection is offered as standard along with a choice of alternatives including G½” male, G¼” female, ¼” NPT male and ½” NPT male.

We are also able to customise the Pi600B barometric pressure sensor / atmospheric pressure sensor to suit your exact requirements if necessary, whilst ensuring a minimal effect on price and availability.

Technical Specifications

Input Pressure Range
Nominal Pressure RangeAbsolute750 to 1250mbar
Permissible OverpressureBar4
Burst PressureBar5
Output Signal & Supply VoltageWiring SystemOutputSupply VoltageInput CurrentInput ResistanceOutput Resistance
Pi6422 – wire4 – 20 mA9 – 32 Vdcn/a<500<500
Pi6053 - wire0 – 5V dc9 – 32 Vdc<6 mA<500<500
Pi60103 - wire0 – 10V dc13 – 32 Vdc<6 mA<500<500
Pi6153 - wire1 – 5V dc9 – 32 Vdc<6 mA<500<500
Pi61103 - wire1 – 10V dc13 – 32 Vdc<6 mA<500<500
Pi6163 - wire1 – 6V dc9 – 32 Vdc<6 mA<500<500
Pi6063 - wire0 – 6V dc9 – 32 Vdc<6 mA<500<500
Pi6453 - wire0.5 to 4.5V dc5 Vdc<6 mA<500<500
Performance
Accuracy (non-linearity, hysteresis, repeatability)% Full Scale Output<±0.25 (BFSL)
<±0.1 (BFSL) optional
Zero Balance±% of Rated Output<1.0
Setting Errors (offsets)2-wire + 3-wireZero & Full Scale, <±0.5% / FS
Permissible Load2-wireRmax = [(VS – VS min) / 0.02] Ω
3-wireRmin = 10 k Ω
Influence EffectsSupply Effects0.5 to 4.5V – Ratiometric, Other Voltage Outputs - <0.005 % FS / 1V
Load Effect4-20mA = <0.05 % FSO / kΩ
Response Time (10% - 90%)ms≤10
Warm-Up Time (amplified versions only)ms2 typ.
Media Temperature˚C-20 to +135 (150 with integrated cooling element)
Ambient Temperature˚C-20 to +80
Storage Temperature˚C-40 to +125
Compensated Temperature Range˚C+20 to +80
Thermal Zero Shift (TZS)% / FS / ˚C<±0.04 (standard)
<±0.02 (option)
Thermal Span Shift (TSS)% output / ˚C<-0.015
Reverse Polarity ProtectionNo damage but also no function
Electromagnetic CompatibilityCE Compliant
Insulation ResistanceMegohms Ω at 50V dc>500
Shock100 g / 11 ms
Vibration10 g RMS (20 ... 2000 Hz)
Housing & process connection303 Stainless Steel
316L Stainless Steel (optional)
High Grade DUPLEX Stainless Steel UNS S31803 (optional)
‘O’ ring sealsViton
NBR/Nitrile (optional)
EPDM (optional)
Chemraz (optional)
DiaphragmCeramic Al2O3 96 % (316L Stainless Steel below 1 bar)
Media wetted partsHousing and process connection, ‘O’ ring seal, diaphragm
Weightgrams100 nominal
Installation positionAny
Operational lifepressure cycles> 100 x 106
Environmental ProtectionIP65, IP67 or IP68
See dimension drawings for details.

Product Dimensions

Pi600B Atmospheric Barometric Pressure Sensor Outline Drawing

All dimensions are in mm

Wiring Details

Small Plug & Socket
(Code A)
Large Plug & Socket
(Code B)
IP65 Cable
(Code C)
AMP 6-pin Bayonnet
(Code D)
IP68 Vented Cable
(Code E)
Binder 6-pin Connector
(Code F)
M12 x 1, 4-pin Connector
(Code G)
2 - wire+ve SupplyPin 1Pin 1RedPin 1RedPin 1Pin 1
-ve SupplyPin 2Pin 2BluePin 2BluePin 2Pin 2
GroundEarth PinEarth PinGreenEarth PinWhitePin 3Pin 3
3 - wire+ve SupplyPin 1Pin 1RedPin 1RedPin 1Pin 1
-ve SupplyPin 2Pin 2BluePin 2BluePin 2Pin 2
+ve OutputPin 3Pin 3GreenPin 3WhitePin 3Pin 3
GroundEarth PinEarth PinYellowEarth PinYellowPin 4Pin 4
4 - wire+ve SupplyPin 1Pin 1RedPin 1RedPin 1Pin 1
-ve SupplyPin 2Pin 2BluePin 2BluePin 2Pin 2
+ve OutputPin 3Pin 3GreenPin 3WhitePin 3Pin 3
-ve OutputEarth PinEarth PinYellowPin 4YellowPin 4Pin 4